Fernsteuerbefehle
R&S
®
RTB2000
346Bedienhandbuch 1333.1611.03 ─ 05
REFLevel:RELative:LOWer <LowerLevel>
REFLevel:RELative:UPPer <UpperLevel>
Set the lower and upper reference levels for rise and fall time mesurements (cursor
and automatic mesurements) if REFLevel:RELative:MODE is set to USER. The
levels are defined as percentages of the high signal level. They are valid for all measu-
rements.
Parameter:
<LowerLevel> *RST: 10
Std.-einheit: %
<UpperLevel> *RST: 90
Std.-einheit: %
REFLevel:RELative:MIDDle <MiddleLevel>
Set the middle reference level that is used for phase and delay measurements, if
REFLevel:RELative:MODE is set to USER. The level is defined as percentages of
the high signal level. The setting is valid for all measurements.
Parameter:
<MiddleLevel> *RST: 50
Std.-einheit: %
15.7.3 Cursor-Messungen
15.7.3.1 Cursor-Einstellungen
CURSor<m>:AOFF........................................................................................................ 346
CURSor<m>:STATe........................................................................................................347
CURSor<m>:SOURce....................................................................................................347
CURSor<m>:FUNCtion...................................................................................................347
CURSor<m>:TRACking[:STATe]...................................................................................... 348
CURSor<m>:X1Position................................................................................................. 348
CURSor<m>:X2Position................................................................................................. 348
CURSor<m>:Y1Position................................................................................................. 349
CURSor<m>:Y2Position................................................................................................. 349
CURSor<m>:YCOupling................................................................................................. 349
CURSor<m>:XCOupling................................................................................................. 349
CURSor<m>:SWAVe...................................................................................................... 349
CURSor<m>:SSCReen.................................................................................................. 349
CURSor<m>:TRACking:SCALe[:STATe]...........................................................................350
CURSor<m>:SPPeak<n>................................................................................................350
CURSor<m>:SNPeak<n>............................................................................................... 350
CURSor<m>:AOFF
Switches the cursor off.