Fernsteuerbefehle
R&S
®
RTB2000
448Bedienhandbuch 1333.1611.03 ─ 05
Parameter:
<DataLength> Bereich: 0 bis 8
Inkrement: 1
*RST: 1
Std.-einheit: Byte
TRIGger:A:CAN:DATA <Data>
Defines the data pattern. The number of bytes in the data pattern is defined with
TRIGger:A:CAN:DLC.
The command is relevant if TRIGger:A:CAN:TYPE is set to IDDT.
Parameter:
<Data> String containing binary pattern with max. 64 bit. Characters 0,
1, and X are allowed. Make sure to enter complete bytes.
TRIGger:A:CAN:ACKerror <AcknowledgeError>
Triggers on acknowledgement errors. An acknowledgement error occurs when the
transmitter does not receive an acknowledgment - a dominant bit during the Ack Slot.
The command is relevant if TRIGger:A:CAN:TYPE is set to ERRCondition.
Parameter:
<AcknowledgeError> ON | OFF
*RST: OFF
TRIGger:A:CAN:BITSterror <BitStuffingError>
Triggers on bit stuffing errors.
See also: "Stopfbit (Stuff Bit)" auf Seite 220.
The command is relevant if TRIGger:A:CAN:TYPE is set to ERRCondition.
Parameter:
<BitStuffingError> ON | OFF
*RST: ON
TRIGger:A:CAN:CRCerror <CRCerror>
Triggers on errors in the Cyclic Redundancy Check.
The command is relevant if TRIGger:A:CAN:TYPE is set to ERRCondition.
Parameter:
<CRCerror> ON | OFF
*RST: OFF