Fernsteuerbefehle
R&S
®
RTB2000
486Bedienhandbuch 1333.1611.03 ─ 05
WGENerator:ARBitrary:UPDate
Loads the waveform from the selected signal source (WGENerator:ARBitrary:
SOURce).
Verwendung: Ereignis
WGENerator:ARBitrary[:FILE]:NAME <FilePath>
Sets the file path and the file for an arbitrary waveform to be loaded.
Parameter:
<FilePath> string
*RST: "
WGENerator:ARBitrary[:FILE]:OPEN
Loads the arbitrary waveform, that is selected with the WGENerator:ARBitrary[:
FILE]:NAME command.
Verwendung:
Ereignis
WGENerator:ARBitrary:VISible <ArbWaveformVisible>
Enables the display of the arbitrary waveform.
Parameter:
<ArbWaveformVisible>ON | OFF
*RST: OFF
WGENerator:MODulation[:ENABLE] <Enable>
Activates or deactivates modulation of the function generator output. To define the
modulation function, see WGENerator:MODulation:FUNCtion.
Parameter:
<Enable> ON | OFF
WGENerator:MODulation:FUNCtion <ModulationFunction>
Selects a function for the modulation.
Parameter:
<ModulationFunction>SINusiod | SQUare | TRIangle | RAMP
WGENerator:MODulation:TYPE <ModulationType>
Sets the modulation type, which defines how the carrier signal is modified.
Signalerzeugung (Option R&S