Remote control commands
R&S
®
RTE
1223User Manual 1326.1032.02 ─ 20
REFCurve<m>:RESCale:VERTical:STATe <State>
Enables and disables the vertical stretching. Stretching changes the display of the
waveform independent of the vertical scale and position.
Suffix:
<m>
.
1..4
Reference waveform
Parameters:
<State> ON | OFF
*RST: OFF
Usage: Asynchronous command
REFCurve<m>:RESCale:VERTical:OFFSet
<Offset>
Moves the reference waveform vertically. Like vertical offset of channel waveforms, the
offset of a reference waveform is subtracted from the measured value.
Suffix:
<m>
.
1..4
Reference waveform
Parameters:
<Offset> Negative values shift the waveform up, positive values shift it
down.
Range: -100E+24 to 100E+24
Increment: 1E-6
*RST: 0
Default unit: V
Usage: Asynchronous command
REFCurve<m>:RESCale:HORizontal:STATe <State>
Enables and disables the horizontal stretching.
Stretching changes the display of the waveform independent of the horizontal settings
of the source waveform and of the horizontal diagram settings.
Suffix:
<m>
.
1..4
Reference waveform
Parameters:
<State> ON | OFF
*RST: OFF
Usage: Asynchronous command