EasyManua.ls Logo

Rohde & Schwarz RTE Series - Page 1270

Rohde & Schwarz RTE Series
2078 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTE
1270User Manual 1326.1032.02 ─ 20
<MeasType>
parameter value
(remote control)
Measurement
(manual opera-
tion)
Description/Result Suffix
<n>
SBWidth Bandwidth n dB down bandwidth; the samples to the left and
right of the peak value are analyzed until the n dB
threshold is exceeded; the frequencies at which the
threshold is exceeded define the limits of the
requested bandwidth
4
not used 5, 6
THD THD[dB] Total harmonic distortion in dB 7
THDPCT THD[%] Total harmonic distortion in % 8
THDA THD_a Is equivalent to THD. Requires option R&S RTE-
K18.
9
THDU THD_u Requires option R&S RTE-K18. 10
THDR THD_r Distortion factor. Requires option R&S RTE-K18. 11
PLISt Peak list List of frequency and peak power value pairs.
Requires option R&S RTE-K18.
12
HAR Harmonic search Returns the measured harmonics. For each har-
monic, the frequency and the value are listed. To get
the number of result pairs (= harmonics), use
MEASurement<m>:RESult:COUNt?.
13
THDF THD_f Root mean square of the sum of all amplitudes of
the harmonic waves in relation to the amplitude at
the fundamental frequency (first harmonic).
Requires option R&S RTE-K18.
14
not used 15
MEASurement<m>:SPECtrum:CPOWer:BANDwidth....................................................... 1271
MEASurement<m>:SPECtrum:OBANdwidth................................................................... 1271
MEASurement<m>:SPECtrum:CPOWer:CFRequency.....................................................1271
MEASurement<m>:SPECtrum:NDBDown...................................................................... 1272
MEASurement<m>:SPECtrum:PEXCursion....................................................................1272
MEASurement<m>:SPECtrum:ATHReshold................................................................... 1272
MEASurement<m>:SPECtrum:RESult<n>:COUNt...........................................................1273
MEASurement<m>:SPECtrum:RESult<n>:MODE........................................................... 1273
MEASurement<m>:RESult:MAXCount........................................................................... 1273
MEASurement<m>:RESult:INVerse............................................................................... 1274
MEASurement<m>:RESult:LABorder............................................................................. 1274
MEASurement<m>:RESult:SHFRequency......................................................................1275
MEASurement<m>:RESult:SHLabels.............................................................................1275
MEASurement<m>:SPECtrum:LCHeck<n>:VALid........................................................... 1276
MEASurement<m>:SPECtrum:LCHeck<n>:LOWer:LIMit................................................. 1276
MEASurement<m>:SPECtrum:LCHeck<n>:UPPer:LIMit.................................................. 1276
MEASurement<m>:SPECtrum:LCHeck<n>:LOWer:MARGin............................................ 1277
MEASurement<m>:SPECtrum:LCHeck<n>:UPPer:MARGin.............................................1277
Automatic measurements