Remote control commands
R&S
®
RTE
1326User Manual 1326.1032.02 ─ 20
DBMS dBms
DBS dBs
DBHZ dBHz
DBKHZ = DBKHz dBkHz
DBMHZ = DBMHz dBMHz
DBGHZ = DBGHz dBGHz
DBA dBA
DBMA dBmA
DBUA dBμA
CALCulate:MATH<m>:FFT:PHASe:SCALe <PhaseScale>
Defines the scaling unit for phase display.
Suffix:
<m>
.
1..8
math waveform
Parameters:
<PhaseScale> DEGRees | RADians
*RST: DEGRees
Usage: Asynchronous command
CALCulate:MATH<m>:FFT:PHASe:SUPPression <Suppression>
Enables noise suppression. Phase calculation is restricted to frequencies with a mini-
mum magnitude, the threshold value (see CALCulate:MATH<m>:FFT:PHASe:
THReshold on page 1326).
Suffix:
<m>
.
1..8
math waveform
Parameters:
<Suppression> ON | OFF
*RST: OFF
Usage: Asynchronous command
CALCulate:MATH<m>:FFT:PHASe:THReshold <SupprThres>
Defines the minimum frequency magnitude for which phases are calculated. This set-
ting is only available if CALCulate:MATH<m>:FFT:PHASe:SUPPression is set to
"ON".