Remote control commands
R&S
®
RTE
1471User Manual 1326.1032.02 ─ 20
Return values:
<FormattedMOSIVal>
Usage: Query only
18.17.4.4 SPI search settings
In search setup commands, you must specify the <SearchName> parameter. It is a
string parameter that contains the search definition name. All commands are similar to
SPI trigger commands.
SEARch:TRIGger:SPI:MODE........................................................................................1471
SEARch:TRIGger:SPI:FCONdition.................................................................................1472
SEARch:TRIGger:SPI:MISopattern................................................................................1472
SEARch:TRIGger:SPI:MOSipattern............................................................................... 1472
SEARch:TRIGger:SPI:DPOPerator................................................................................1472
SEARch:TRIGger:SPI:DPOSition...................................................................................1473
SEARch:TRIGger:SPI:DPTO.........................................................................................1473
SEARch:TRIGger:SPI:PALignment................................................................................ 1473
SEARch:TRIGger:SPI:MODE <SearchName>,<Type>
SEARch:TRIGger:SPI:MODE? <SearchName>
Sets the event to be searched for.
Parameters:
<Type> SSACtive | TIMeout | MOSI | MISO | MOMI
SSACtive
Searches for the start of the frame when slave select signal SS
changes to the active state. This type is available if the slave
select line is configured in the bus setup, and BUS<m>:SPI:
FRCondition is SS.
TIMeout
Searches for the start of the frame when the clock idle time
exceeds the timeout. This type is available if the slave select line
is configured in the bus setup, and BUS<m>:SPI:
FRCondition is CLKTimeout.
MOSI | MISO
Searches for a specified data pattern expected on the MOSI line
or on the MISO line, respectively.
MOMI
Searches in parallel for specified data patterns expected on the
MOSI and MISO lines.
*RST:
SSACtive
Parameters for setting and query:
<SearchName>
Usage: Asynchronous command