TRIGger<m>:LIN:IDOR<n>[:VALue] <IdPattern>
Defines the pattern of the indicated IDOR identifier in the "identifier OR" trigger condi-
tion.
Suffix:
<n>
.
1..4
Index of the identifier in an "identifier OR" condition
Parameters:
<IdPattern> Numeric or string pattern, see Chapter 18.4.6, "Bit pattern
parameter", on page 1076. The parameter accepts the bit value
X (don't care).
TRIGger<m>:LIN:SYERror <SyncError>
Triggers if a synchronization error occurs.
The trigger type has to be set before: TRIGger<m>:LIN:TYPE to ERRC.
Parameters:
<SyncError> ON | OFF
*RST: ON
TRIGger<m>:LIN:IPERror <IdParityError>
Triggers if an error occurs in the identifier parity bits. These are the bits 6 and 7 of the
identifier.
The trigger type has to be set before: TRIGger<m>:LIN:TYPE to ERRC.
Parameters:
<IdParityError> ON | OFF
*RST: ON
TRIGger<m>:LIN:CHKSerror <ChecksumError>
Triggers on checksum errors according to the LIN standard set with BUS<m>:LIN:
STANdard.
The trigger type has to be set before: TRIGger<m>:LIN:TYPE to ERRC.
The frame identifier must be set with TRIGger<m>:LIN:ERRPattern on page 1537
and the data length with TRIGger<m>:LIN:CRCDatalen on page 1537.
Parameters:
<ChecksumError> ON | OFF
*RST: ON