EasyManua.ls Logo

Rohde & Schwarz RTE Series - Page 1551

Rohde & Schwarz RTE Series
2078 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTE
1551User Manual 1326.1032.02 ─ 20
Parameters:
<IdParityError> ON | OFF
*RST: ON
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:LIN:SYERror <SearchName>,<SyncError>
SEARch:TRIGger:LIN:SYERror? <SearchName>
Searches for synchronization errors.
Parameters:
<SyncError> ON | OFF
*RST: ON
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:LIN:CHKSerror <SearchName>,<ChecksumError>
SEARch:TRIGger:LIN:CHKSerror? <SearchName>
Searches for checksum errors according to the LIN standard.
Use the following commands to configure the checksum error search:
SEARch:TRIGger:LIN:ERRPattern on page 1551
SEARch:TRIGger:LIN:CRCDatalen on page 1552
SEARch:TRIGger:LIN:STANdard on page 1552
Parameters:
<ChecksumError> ON | OFF
*RST: ON
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:LIN:ERRPattern <SearchName>,<ErrorPattern>
SEARch:TRIGger:LIN:ERRPattern? <SearchName>
Sets the frame identifier to search for a checksum error.
Parameters:
<ErrorPattern> Numeric or string pattern, see Chapter 18.4.6, "Bit pattern
parameter", on page 1076.
Parameters for setting and query:
<SearchName>