Remote control commands
R&S
®
RTE
1648User Manual 1326.1032.02 ─ 20
Query parameters:
<SearchName>
Return values:
<SDI> Range: 0 to 3
Increment: 1
*RST: 0
Usage: Query only
SEARch:RESult:ARINc:WORD<m>:STATe? <SearchName>
Suffix:
<m>
.
*
Query parameters:
<SearchName>
Return values:
<FrameState> OK | CODE | GAP | PAR
*RST: OK
Usage: Query only
SEARch:RESult:ARINc:WORD<m>:STARt? <SearchName>
Suffix:
<m>
.
*
Query parameters:
<SearchName>
Return values:
<FrameStart> Range: -100E+24 to 100E+24
Increment: 100E-12
*RST: 0
Default unit: s
Usage: Query only
18.17.12 Ethernet 10BASE-T and 100BASE-TX (option R&S RTE-K8)
● Configuration.......................................................................................................1648
● Trigger.................................................................................................................1651
● Decode results.................................................................................................... 1656
● Search settings................................................................................................... 1662
● Search results..................................................................................................... 1667
18.17.12.1 Configuration
In all BUS<m>:ETHernet commands, the suffix <m> selects the serial bus.
Protocols