Remote control commands
R&S
®
RTE
1705User Manual 1326.1032.02 ─ 20
Suffix:
<m>
.
1..4
Selects the serial data bus.
Parameters:
<CRCVersion> LEGA | V2010
Legacy: method used up to 2010
V2010: current method
*RST: V2010
BUS<m>:SENT:CRCMethod <CRCCalculation>
Selects the calculation method for the CRC checksum.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<CRCCalculation> SAEJ | TLE
SAEJ: according to the standard
TLE: according to the computing method for TLE_4998X sen-
sors.
*RST: SAEJ
BUS<m>:SENT:PPULse <PausePulse>
Determines if a pause pulse is part of the SENT transmission sequence.
Suffix:
<m>
.
1..4
Selects the serial data bus.
Parameters:
<PausePulse> NPP | PP | PPFL
NPP
Transmits the SENT message without pause pulse.
PP
Transmits the message with a fixed pulse length, automatically
calculated.
PPFL
Transmits the pause pulse with a user-defined frame length to
obtain a transmission sequence with constant length.
*RST: PPFL
BUS<m>:SENT:PPFLength <FrameLength>
Defines a constant transmission sequence length. To select the fixed sequence length,
set BUS:SENT:PPUL PPFL.
Protocols