Remote control commands
R&S
®
RTE
1724User Manual 1326.1032.02 ─ 20
INRange | OORange
In range / Out of range. To define the range set the minimum
and maximum values with SEARch:TRIGger:SENT:SIMN and
SEARch:TRIGger:SENT:SIMX.
*RST: EQUal
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:SENT:SIMN <SearchName>,<SMIDPattern>
SEARch:TRIGger:SENT:SIMN? <SearchName>
Specifies a message identifier pattern, or sets the start value of an identifier range.
Parameters:
<SMIDPattern> Numeric or string pattern, Chapter 18.4.6, "Bit pattern parame-
ter", on page 1076. The string parameter accepts the bit value X
(don't care).
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:SENT:SIMX <SearchName>,<SMIDPatternTo>
SEARch:TRIGger:SENT:SIMX? <SearchName>
Sets the end value of an identifier range for SEARch:TRIGger:SENT:SICN
INRange or OORange.
Parameters:
<SMIDPatternTo> Numeric or string pattern, Chapter 18.4.6, "Bit pattern parame-
ter", on page 1076. The string parameter accepts the bit value X
(don't care).
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:SENT:SDCN <SearchName>,<SMDataOperator>
SEARch:TRIGger:SENT:SDCN? <SearchName>
Sets the operator to set a specific data pattern or a data pattern range.
Parameters:
<SMDataOperator> EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater than,
Greater or equal than. These conditions require one data pattern
to be set with SEARch:TRIGger:SENT:SDMN.