Remote control commands
R&S
®
RTE
1861User Manual 1326.1032.02 ─ 20
Suffix:
<m>
.
1..3
Parameters:
<TimeOperator> EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These conditions require one data pattern
to be set with the corresponding TRIGger<m>:SWIRe:TIME:
MIN command.
INRange | OORange
In range/Out of range: set the minimum and maximum value of
the range with TRIGger<m>:SWIRe:TIME:MIN and
TRIGger<m>:SWIRe:TIME:MAX.
*RST:
EQUal
TRIGger<m>:SWIRe:TIME:MAX
<TimePatternMax>
Sets the the end value of a data value for the time code range if TRIGger<m>:
SWIRe:TIME:CONDition is set to INRange or OORange.
Suffix:
<m>
.
1..3
Parameters:
<TimePatternMax>
TRIGger<m>:SWIRe:TIME:MIN <TimePatternMin>
Specifies a pattern for the data value for the time code, or sets the the start value of a
pattern range.
Suffix:
<m>
.
1..3
Parameters:
<TimePatternMin>
TRIGger<m>:SWIRe:TYPE <Type>
Sets the trigger type for the SpaceWire analysis.
Suffix:
<m>
.
1..3
Parameters:
<Type> CTRL | DATA | NULL | TIME | ERRor
*RST: CTRL
Protocols