Remote control commands
R&S
®
RTE
1909User Manual 1326.1032.02 ─ 20
BUS<m>:PARallel:CLON <Clocked>
Defines if the bus is a clocked bus - one of the digital channels serves as clock of the
bus.
Suffix:
<m>
.
1 | 2
Selects the parallel bus. The clocked bus is available on parallel
buses 1 and 2.
Parameters:
<Clocked> ON | OFF
*RST: OFF
BUS<m>:PARallel:CLOCk
<ClockSource>
Selects the digital channel used as clock of the indicated parallel bus.
Suffix:
<m>
.
1 | 2
Selects the parallel bus. The clocked bus is available on parallel
buses 1 and 2.
Parameters:
<ClockSource> D0 | D1 | D2 | D3 | D4 | D5 | D6 | D7 | D8 | D9 | D10 | D11 | D12 |
D13 | D14 | D15
Clock channel
*RST: D1
BUS<m>:PARallel:CLSLope <ClockSlope>
Selects the slope of the clock signal at which all digital channels of the bus are ana-
lyzed.
Suffix:
<m>
.
1 | 2
Selects the parallel bus. The clocked bus is available on parallel
buses 1 and 2.
Parameters:
<ClockSlope> POSitive | NEGative | EITHer
*RST: POSitive
BUS<m>:PARallel:CLEar
Removes all assigned digital channels from the bus