Remote control commands
R&S
®
RTE
1942User Manual 1326.1032.02 ─ 20
Suffix:
<m>
.
1..2
Specifies the master generator.
Parameters:
<CoupleAll> ON | OFF
*RST: OFF
WGENerator<m>:COUPling:AMPLitude <CoupleAmplitude>
Enables the coupling of all amplitude parameters of the generators.
Suffix:
<m>
.
1..2
Specifies the master generator.
Parameters:
<CoupleAmplitude> ON | OFF
*RST: OFF
WGENerator<m>:COUPling:OUTPut CoupleAllOutput
Couples all parameters including output enable, but excluding inversion and load.
Suffix:
<m>
.
1..2
Specifies the master generator.
Parameters:
CplAllWthEnab ON | OFF
*RST: OFF
WGENerator<m>:COUPling:PHASeshift <PhaseShift>
Sets the phase shift between the waveform of Gen1 and Gen2 when the frequency
parameters of the two waveforms are coupled.
Suffix:
<m>
.
1..2
Specifies the master generator.
Parameters:
<PhaseShift> Range: -180 to 180
Increment: 1
*RST: 0
Default unit: °
WGENerator<m>:COUPling[:FREQuency] <CoupleFrequency>
Enables the coupling of all frequency parameters of the generators.