Remote control commands
R&S
®
RTE
1957User Manual 1326.1032.02 ─ 20
<n> *
Return values:
<Value> Range: -1000 to 1000
*RST: 0
Default unit: A
Usage: Query only
POWer:HARMonics:STAN <StandardInUse>
Sets a standard for the current harmonic measurement.
Parameters:
<StandardInUse> ENA | ENB | ENC | END | MIL | RTC
*RST: ENA
POWer:HARMonics:VOLT <DOADisplayResult>
Selects if the voltage results are displayed or not for "Standard" > "RTCA DO-160" and
enabled "Evaluation with voltage source and revised current law".
Parameters:
<DOADisplayResult> VOLTDISP | NOVOLTDISP
*RST: NOVOLTDISP
Example:
POW:HARM:STAN RTC
POW:HARM:EVAL REVISED
POW:HARM:VOLT NOVOLTDISP
Selects an evaluation with the revised current law and no volt-
age display.
18.20.7 Modulation analysis
This measurement is a single shot measurement. To start the measurement, use the
RUNS command.
POWer:MODulation:AUTO............................................................................................1958
POWer:MODulation:DHIStogram...................................................................................1958
POWer:MODulation:EXECute....................................................................................... 1958
POWer:MODulation:REPort:ADD...................................................................................1958
POWer:MODulation:RESult:ACTual?............................................................................. 1958
POWer:MODulation:RESult:AVG?................................................................................. 1958
POWer:MODulation:RESult:EVTCount?.........................................................................1958
POWer:MODulation:RESult:NPEak?..............................................................................1958
POWer:MODulation:RESult:PPEak?..............................................................................1958
POWer:MODulation:RESult:RMS?.................................................................................1958
POWer:MODulation:RESult:STDDev?............................................................................1958
Power analysis (option R&S