EasyManua.ls Logo

Rohde & Schwarz RTE Series - FFT Coupling

Rohde & Schwarz RTE Series
2078 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Spectrum analysis
R&S
®
RTE
416User Manual 1326.1032.02 ─ 20
Suppression
Enables noise suppression. Phase calculation is restricted to frequencies with a mini-
mum magnitude, the threshold value.
Remote command:
CALCulate:MATH<m>:FFT:PHASe:SUPPression on page 1326
Threshold
Defines the minimum frequency magnitude for which phases are calculated. This set-
ting is only available if "Suppression" is enabled.
Remote command:
CALCulate:MATH<m>:FFT:PHASe:THReshold on page 1326
9.1.3.6 FFT coupling
Access: [MATH] > "FFT Coupling"
Up to four spectrum displays can be shown simultaneously, one for each math wave-
form. The settings for one or more spectrums can be coupled. Thus, if any FFT setting
for any of the coupled spectrums are changed, they are changed for all coupled spec-
trums.
Enable math signal
If activated, a diagram for the defined math waveform is displayed on the touch screen.
Remote command:
CALCulate:MATH<m>:STATe on page 1227
FFT analysis

Table of Contents

Other manuals for Rohde & Schwarz RTE Series

Related product manuals