Mask testing
R&S
®
RTE
438User Manual 1326.1032.02 ─ 20
With the graphical method, you can:
Move, add, and delete segments
Move and delete points
Adding points to an existing segment graphically is not possible.
With the numerical method, in the "Mask Definition" tab, you have all modification pos-
sibilities. You can delete and add points and segments, change the coordinates, and
also stretch a segment, or move it by adding an offset.
To add a mask segment on the touch screen
1. Tap a mask segment of the mask test that you want to complement.
2. Tap the "Masks" icon on the toolbar.
3. Tap the corner points of the new mask segment on the touch screen.
4. To finish the segment and mask definition, double-tap the last point, or tap the
"Select" icon on the toolbar.
To delete a mask segment on the touch screen
1. On the toolbar, tap the "Delete" icon.
2. Tap the mask segment you want to delete.
To delete a point on the touch screen
1. Tap the mask segment from which you want to delete a point.
The selected segment is now in definition mode, shown with blue color.
2. On the toolbar, tap the "Delete" icon.
3. Tap the point you want to delete.
To move a segment on the touch screen
1. Drag&drop the segment to the new position.
2. Tap outside the mask to deselect the mask segment.
Working with masks