Mixed signal option (MSO, R&S RTE-B1)
R&S
®
RTE
911User Manual 1326.1032.02 ─ 20
Type
Depending on the selected source, the instrument provides the appropriate trigger
types and the corresponding trigger settings. For mixed signal analysis, the following
trigger types are available:
●
Edge, see page 911
●
Width, see page 912
●
Timeout, see page 913
●
Data2Clock, see page 914
●
State, see page 915
●
Pattern, see page 916
●
Serial pattern, see page 919
Remote command:
TRIGger<m>:PARallel:TYPE on page 1913
14.3.1.2 Edge
Using the edge trigger, you can also trigger on a single digital channel (a logic bit), and
a logical combination of digital channels.
Depending on the selected trigger source, different trigger settings are available. The
trigger level is already set - in MSO the logical threshold is used as trigger level.
Figure 14-1: Edge trigger settings for trigger source = logical combination of digital channels (Logic)
Slope
Defines the edge - the state transition - of the signal.
"Rising"
Means a 0 to 1 transition of the state.
"Falling"
Means a 1 to 0 transition of the state.
"Either"
Triggers on any activity on the selected trigger source.
Remote command:
TRIGger<m>:PARallel:EDGE:SLOPe on page 1914
Logical expression
Defines a logical combination of several digital channels as trigger condition if "Logic"
is set for "Source".
If the "Slope" is rising, the trigger occurs when the logical expression comes true. If the
"Slope" is falling, the trigger occurs when the logical expression comes false.
Remote command:
TRIGger<m>:PARallel:EDGE:EXPRession[:DEFine] on page 1913
Trigger