Remote control commands
R&S
®
RTE
1763User Manual 1326.1032.02 ─ 20
Return values:
<NumWords> Range: 0 to 4294967295
Increment: 1
*RST: 0
Usage: Query only
BUS<m>:CMSB:RESult<n>:CELL<o>:NAME?
Returns the name of the specified cell. Cell names are not necessarily unique.
Suffix:
<m>
.
1..4
<n> *
<o> *
Return values:
<Name>
Usage: Query only
BUS<m>:CMSB:RESult<n>:CELL<o>:STARt?
Returns the start time of the selected cell.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
<o> *
Selects the cell.
Return values:
<Start> Range: -100E+24 to 100E+24
Increment: 100E-12
*RST: 0
Default unit: s
Usage: Query only
BUS<m>:CMSB:RESult<n>:CELL<o>:STOP?
Returns the end time of the selected cell.