Remote control commands
R&S
®
RTE
1814User Manual 1326.1032.02 ─ 20
SEARch:TRIGger:USB:CRC16error <SearchName>,<CRC16Error>
SEARch:TRIGger:USB:CRC16error? <SearchName>
Defines, whether a search for any CRC16 error shall be activated or not.
Parameters:
<CRC16Error> ON | OFF
*RST: OFF
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:USB:CRC5error
<SearchName>,<CRC5Error>
SEARch:TRIGger:USB:CRC5error? <SearchName>
Defines, whether a search for any CRC5 error shall be activated or not.
Parameters:
<CRC5Error> ON | OFF
*RST: OFF
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:USB:DATA <SearchName>,<USBDataType>
SEARch:TRIGger:USB:DATA? <SearchName>
Defines, which data packet type is searched for: "DATA0", "DATA1", "DATA2", or
"MDATA", as well as "Any" data packet.
Parameters:
<USBDataType> ANY | D0 | D1 | D2 | MD
ANY
Searches for any of the data packet types listed below
D0
Searches for a DATA0 packet (even PID)
D1
Searches for a DATA1 packet (odd PID)
D2
Searches for a DATA2 packet (high-speed data packet for high
bandwidth isochronous transaction in a microframe)
MD
Searches for an MDATA packet (high-speed data packet for split
and high bandwidth isochronous transactions)
*RST:
D0
Parameters for setting and query:
<SearchName>
Protocols