Remote control commands
R&S
®
RTE
1856User Manual 1326.1032.02 ─ 20
BUS<m>:SWIRe:BPOSition <SyncBitPos>
Sets the bit position, the align position for the manual synchronisation mode. This can
be useful when parity errors exist in the signal, and parity check is the main indicator
for the decoder to do packet alignment.
Suffix:
<m>
.
1..4
Parameters:
<SyncBitPos> Range: 0 to 10
Increment: 1
*RST: 0
BUS<m>:SWIRe:DATA:HYSTeresis <HysteresisData>
Sets a value for the hysteresis of the data signal.
Suffix:
<m>
.
1..4
Parameters:
<HysteresisData> Range: 0 to 0.8
Increment: 0.01
*RST: 0.2
Default unit: V
BUS<m>:SWIRe:DATA:SOURce <SourceData>
Selects the source of the data signal.
Suffix:
<m>
.
1..4
Parameters:
<SourceData> C1W1 | C2W1 | C3W1 | C4W1 | M1 | M2 | M3 | M4 | M5 | M6 |
M7 | M8 | R1 | R2 | R3 | R4 | D0 | D1 | D2 | D3 | D4 | D5 | D6 |
D7 | D8 | D9 | D10 | D11 | D12 | D13 | D14 | D15
*RST: C1W1
BUS<m>:SWIRe:DATA:THReshold <ThresholdData>
Sets the threshold value for the digitization of the data signal.
Suffix:
<m>
.
1..4
Parameters:
<ThresholdData> Range: -10 to 10
Increment: 0.1
*RST: 1.25
Default unit: V