Acquisition and waveform setup
R&S
®
RTE
197User Manual 1326.1032.02 ─ 20
The settings for active voltage probes with Rohde & Schwarz probe interface are:
Probe unit, Auto attenuation........................................................................................197
Micro button action......................................................................................................197
ProbeMeter................................................................................................................. 198
Probe unit, Auto attenuation
If the probe is recognized by the R&S RTE, the instrument reads the attenuation unit
and value from the probe an displays them.
Remote command:
PROBe<m>:SETup:ATTenuation[:AUTO]? on page 1125
TRPRobe:SETup:ATTenuation[:AUTO]? on page 1125 (trigger input)
Micro button action
Active voltage probes with Rohde & Schwarz probe interface have a configurable
micro button on the probe head. Pressing this button, you start an action on the instru-
ment directly from the probe. The button is disabled during internal automatic pro-
cesses, for example, during self-alignment, autoset, and find level.
Select the action that you want to start from the probe: