Remote control commands
R&S
®
RTP
1274User Manual 1337.9952.02 ─ 12
The pattern is defined using the commands:
TRIGger<m>:QUALify<n>:A[:ENABle] on page 1301
TRIGger<m>:QUALify<n>:A:LOGic on page 1302
TRIGger<m>:QUALify<n>:AB:LOGic on page 1303
These are the commands for channel 1, use the similar commands for channels 2, 3,
and 4.
TRIGger<m>:PATTern:MODE........................................................................................1274
TRIGger<m>:PATTern:TIMeout:MODE...........................................................................1274
TRIGger<m>:PATTern:TIMeout[:TIME]........................................................................... 1275
TRIGger<m>:PATTern:WIDTh:RANGe........................................................................... 1275
TRIGger<m>:PATTern:WIDTh[:WIDTh]...........................................................................1276
TRIGger<m>:PATTern:WIDTh:DELTa.............................................................................1276
TRIGger<m>:PATTern:MODE <Mode>
Adds additional time limitation to the pattern definition.
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
Parameters:
<Mode> OFF | TIMeout | WIDTh
OFF
No time limitation. The event occurs if the pattern condition is
fulfilled.
TIMeout
Defines how long the result of the pattern condition must be true
or false. The duration of the timeout is defined using
TRIGger<m>:PATTern:TIMeout[:TIME].
WIDTh
Defines a time range for keeping up the true result of the pattern
condition. The range is defined using TRIGger<m>:PATTern:
WIDTh:RANGe.
*RST:
OFF
Usage: Asynchronous command
TRIGger<m>:PATTern:TIMeout:MODE <TimeoutMode>
Defines the condition for the timeout.
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
Parameters:
<TimeoutMode> HIGH | LOW
Trigger