Remote control commands
R&S
®
RTP
1322User Manual 1337.9952.02 ─ 12
Parameters for setting and query:
<DiagramName> Name of the diagram on which the zoom area is based.
<ZoomName> Name of the zoom diagram
Usage: Asynchronous command
LAYout:ZOOM:HORZ:RELative:POSition <DiagramName>,
<ZoomName>,<RelPosi>
LAYout:ZOOM:HORZ:RELative:POSition? <DiagramName>, <ZoomName>
Defines the x-value of the centerpoint of the zoom area.
Parameters:
<RelPosi> Relative position of the centerpoint (x-value)
Range: 0 to 100
Increment: 0.1
*RST: 100
Default unit: %
Parameters for setting and query:
<DiagramName> Name of the diagram on which the zoom area is based.
<ZoomName> Name of the zoom diagram
Example: See Chapter 22.3.1.2, "Creating zoom diagrams", on page 1127
Usage: Asynchronous command
LAYout:ZOOM:HORZ:RELative:SPAN <DiagramName>,
<ZoomName>,<RelativeSpan>
LAYout:ZOOM:HORZ:RELative:SPAN? <DiagramName>, <ZoomName>
Defines the width of the zoom area.
Parameters:
<RelativeSpan> Range: 1E-15 to 100
Increment: 0.1
*RST: 1
Default unit: %
Parameters for setting and query:
<DiagramName> Name of the diagram on which the zoom area is based.
<ZoomName> Name of the zoom diagram
Example: See Chapter 22.3.1.2, "Creating zoom diagrams", on page 1127
Usage: Asynchronous command
Waveform analysis