Remote control commands
R&S
®
RTP
1343User Manual 1337.9952.02 ─ 12
<n> 1..3
Selects the waveform. If [:WAVeform<n>] is omitted, waveform 1
is adressed.
Parameters:
<StrtAcqIdx> The start index is always negative.
Range: 0 to -(n-1)
Increment: 1
Usage: Asynchronous command
CHANnel<m>[:WAVeform<n>]:HISTory:STOP <StpAcqIdx>
Sets the index of the latest segment to be displayed in the history viewer.
Suffix:
<m>
.
1..4
Selects the input channel.
<n> 1..3
Selects the waveform. If [:WAVeform<n>] is omitted, waveform 1
is adressed.
Parameters:
<StpAcqIdx> Index of the stop acquisition. The newest acquisition always has
the index "0".
Range: 0 to -(n-1)
Increment: 1
Usage: Asynchronous command
CHANnel<m>[:WAVeform<n>]:HISTory:TPACq <TimePerAcq>
Sets the display time for one acquisition. The shorter the time, the faster is the replay.
Suffix:
<m>
.
1..4
Selects the input channel.
<n> 1..3
Selects the waveform. If [:WAVeform<n>] is omitted, waveform 1
is adressed.
Parameters:
<TimePerAcq> Range: 40E-6 to 10
Increment: 1
*RST: 0.05
Default unit: s
Usage: Asynchronous command