Remote control commands
R&S
®
RTP
1394User Manual 1337.9952.02 ─ 12
MEASurement<m>:SPECtrum:NDBDown <NDbDown>
Defines the threshold until which the samples to the left and right of the peak value are
analyzed in order to determine the "N dB down bandwidth".
Suffix:
<m>
.
1..10
See "Selection of the measurement group: MEASurement<m>"
on page 1359.
Parameters:
<NDbDown> Range: 0 to 100
Increment: 1
*RST: 20
Default unit: dB
Usage: Asynchronous command
MEASurement<m>:SPECtrum:PEXCursion
<Value>
Defines a relative threshold, the minimum level value by which the waveform must rise
or fall to be considered as a peak. To avoid identifying noise peaks, enter a peak
excursion value that is higher than the noise levels.
Suffix:
<m>
.
1..10
The suffix is irrelevant.
Parameters:
<Value>
Usage: Asynchronous command
Firmware/software: Version 2.70
MEASurement<m>:SPECtrum:ATHReshold <Value>
Defines an absolute threshold as an additional condition for the peak search. Only
peaks that exceed the threshold are detected.
This setting is only available for spectrum waveforms. It is valid for cursor measure-
ments, spectrum measurements and peak search.
Suffix:
<m>
.
1..10
See "Selection of the measurement group: MEASurement<m>"
on page 1359.
Parameters:
<Value> numeric value
Default unit: dBm
Usage: Asynchronous command