Remote control commands
R&S
®
RTP
1399User Manual 1337.9952.02 ─ 12
LAYout:HISTogram:VERTical:RELative:STOP................................................................. 1403
LAYout:HISTogram:RESet.............................................................................................1404
LAYout:HISTogram:REMove..........................................................................................1404
LAYout:HISTogram:ADD <HistogramName>, <Source>, <XStart>, <XStop>,
<YStart>, <YStop>, <Relative>, <Orientation>
Defines and displays a new histogram for the specified source.
Note: To define the mode of the histogram (vertical or horizontal), use the LAYout:
HISTogram:MODE command.
For numerical values, the input of a unit is not supported for this command.
Setting parameters:
<HistogramName> String defining the histogram name which is used to refer to the
histogram by other functions.
<Source> C1W1 | C1W2 | C1W3 | C2W1 | C2W2 | C2W3 | C3W1 | C3W2 |
C3W3 | C4W1 | C4W2 | C4W3 | M1 | M2 | M3 | M4 | M5 | M6 |
M7 | M8 | R1 | R2 | R3 | R4 | MRESult1 | MRESult2 | MRESult3 |
MRESult4 | MRESult5 | MRESult6 | MRESult7 | MRESult8 |
SG1TL1 | SG1TL2 | SG2TL1 | SG2TL2 | SG3TL1 | SG3TL2 |
SG4TL1 | SG4TL2 | SG5TL2 | SG6TL1 | SG6TL2 | SG7TL1 |
SG7TL2 | SG8TL1 | SG8TL2 | Z1V1 | Z1V2 | Z1V3 | Z1V4 |
Z1I1 | Z1I2 | Z1I3 | Z1I4 | Z2V1 | Z2V2 | Z2V3 | Z2V4 | Z2I1 |
Z2I2 | Z2I3 | Z2I4 | DIFF1 | DIFF2 | COMMON1 | COMMON2 |
EYE1 | EYE2 | EYE3 | EYE4 | SRHist1 | SDHist1 | TJHist1 |
DJHist1 | DDJHist1 | PJOHist1 | RJOHist1 | SEYE1 | SRHist2 |
SDHist2 | TJHist2 | DJHist2 | DDJHist2 | PJHOist2 | RJOHist2 |
SEYE2 | TNHist1 | DNHist1 | DDNHist1 | PNHist1 | RNOHist1 |
TNHist2 | DNHist2 | DDNHist2 | PNHist2 | RNOHist2 |
PJDHist1 | BUJHist1 | RJHist1 | PJDHist2 | BUJHist2 | RJHist2 |
PNDHist1 | BUNHist1 | RNHist1 | PNDHist2 | BUNHist2 |
RNHist2
Data source of the histogram, see Chapter 22.4.2, "Waveform
parameter", on page 1145
<XStart>
Defines the start value of the x-value range.
<XStop> Defines the stop value of the x-value range.
<YStart> Defines the start value of the y-value range.
<YStop> Defines the stop value of the y-value range.
<Relative> ON | OFF
Defines whether relative or absolute values are used for the
value range definition.
<Orientation> VERTical | HORizontal
Example: See "Creating and reading histograms" on page 1130