Remote control commands
R&S
®
RTP
1443User Manual 1337.9952.02 ─ 12
CALCulate:MATH<m>:FFT:BANDwidth[:RESolution]:RATio..............................................1446
CALCulate:MATH<m>:FFT:BANDwidth[:RESolution][:VALue]........................................... 1446
CALCulate:MATH<m>:FFT:WINDow:TYPE.....................................................................1446
CALCulate:MATH<m>:FFT:FRAMe:ARIThmetics............................................................ 1448
CALCulate:MATH<m>:FFT:FRAMe:COVerage?.............................................................. 1448
CALCulate:MATH<m>:FFT:FRAMe:MAXCount............................................................... 1448
CALCulate:MATH<m>:FFT:FRAMe:OFACtor.................................................................. 1449
CALCulate:MATH<m>:FFT:GATE:COUPling...................................................................1449
TIMebase:RACTime?................................................................................................... 1450
CALCulate:MATH<m>:FFT:GATE:ABSolute:STARt..........................................................1450
CALCulate:MATH<m>:FFT:GATE:ABSolute:STOP.......................................................... 1450
CALCulate:MATH<m>:FFT:GATE:MODE........................................................................1450
CALCulate:MATH<m>:FFT:GATE:RELative:STARt.......................................................... 1451
CALCulate:MATH<m>:FFT:GATE:RELative:STOP...........................................................1451
CALCulate:MATH<m>:FFT:GATE:ZCOupling..................................................................1451
CALCulate:MATH<m>:FFT:GATE[:STATe]...................................................................... 1452
CALCulate:MATH<m>:FFT:MAGNitude:LEVel.................................................................1452
CALCulate:MATH<m>:FFT:MAGNitude:RANGe..............................................................1452
CALCulate:MATH<m>:FFT:MAGNitude:SCALe...............................................................1452
CALCulate:MATH<m>:FFT:PHASe:SCALe.....................................................................1453
CALCulate:MATH<m>:FFT:PHASe:SUPPression............................................................ 1454
CALCulate:MATH<m>:FFT:PHASe:THReshold............................................................... 1454
CALCulate:MATH<m>:FFT:PHASe:UNWRap..................................................................1454
CALCulate:MATH<m>:FFT:COUPled:WITH<1..8>...........................................................1455
CALCulate:MATH<m>:FFT:LOGScale <XAxisMode>
Defines the scaling method for the frequency (x-)axis of the spectrogram.
This command is only available if option R&S RTP-K37 is installed.
Suffix:
<m>
.
1..8
Parameters:
<XAxisMode> LIN | LOG
LOG
Logarithmic scaling
LIN
Linear scaling
*RST: LIN
Usage: Asynchronous command
CALCulate:MATH<m>:FFT:STARt <StartFreq>
Defines the start frequency of the displayed frequency span.
Suffix:
<m>
.
1..8
math waveform
Spectrum analysis