Remote control commands
R&S
®
RTP
1461User Manual 1337.9952.02 ─ 12
Parameters:
<Source> C1W1 | C1W2 | C1W3 | C2W1 | C2W2 | C2W3 | C3W1 | C3W2 |
C3W3 | C4W1 | C4W2 | C4W3 | M1 | M2 | M3 | M4 | M5 | M6 |
M7 | M8 | R1 | R2 | R3 | R4 | XY1 | XY2 | XY3 | XY4 | SG1TL1 |
SG1TL2 | SG2TL1 | SG2TL2 | SG3TL1 | SG3TL2 | SG4TL1 |
SG4TL2 | SG5TL1 | SG5TL2 | SG6TL1 | SG6TL2 | SG7TL1 |
SG7TL2 | SG8TL1 | SG8TL2 | Z1V1 | Z1V2 | Z1V3 | Z1V4 |
Z1I1 | Z1I2 | Z1I3 | Z1I4 | Z2V1 | Z2V2 | Z2V3 | Z2V4 | Z2I1 |
Z2I2 | Z2I3 | Z2I4 | DIFF1 | DIFF2 | COMMON1 | COMMON2 |
EYE1 | EYE2 | EYE3 | EYE4 | SEYE1 | SEYE2
Waveform to be tested, see Chapter 22.4.2, "Waveform parame-
ter", on page 1145
*RST:
C1W1
Parameters for setting and query:
<MaskTestName> String containing the name of the mask test
Usage: Asynchronous command
MTESt:CONDition <MaskTestName>,<PassFailMode>
MTESt:CONDition? <MaskTestName>
Sets the first criteria for a failed test, the kind of hits to be considered for test evalua-
tion. A test has failed if the number of sample hits or acquisition hits exceeds the limit
defined by MTESt:TOLerance.
Parameters:
<PassFailMode> SAMPles | ACQuisitions
SAMPles
Considers the number of samples that hit the mask.
ACQuisitions
Considers the number of acquisitions that contain at least one
sample hit. How many samples hit the mask in that acquisition is
not relevant.
*RST: SAMPles
Parameters for setting and query:
<MaskTestName> String with the name of the mask test
Usage: Asynchronous command
MTESt:TOLerance <MaskTestName>,<TolViolCnt>
MTESt:TOLerance? <MaskTestName>
Sets the second criteria for a failed test, the number of tolerable sample hits or acquisi-
tion hits. Use MTESt:CONDition to define which hits are considered for test evalua-
tion.
Mask testing