Remote control commands
R&S
®
RTP
1726User Manual 1337.9952.02 ─ 12
SEARch:RESult:ARINc:WORD<m>:STOP? <SearchName>
Suffix:
<m>
.
*
Query parameters:
<SearchName>
Return values:
<FrameStop> Range: -100E+24 to 100E+24
Increment: 100E-12
*RST: 0
Default unit: s
Usage: Query only
SEARch:RESult:ARINc:WORD<m>:SDI?
<SearchName>
Suffix:
<m>
.
*
Query parameters:
<SearchName>
Return values:
<SDI> Range: 0 to 3
Increment: 1
*RST: 0
Usage: Query only
SEARch:RESult:ARINc:WORD<m>:STATe? <SearchName>
Suffix:
<m>
.
*
Query parameters:
<SearchName>
Return values:
<FrameState> OK | CODE | GAP | PAR
*RST: OK
Usage: Query only
SEARch:RESult:ARINc:WORD<m>:STARt? <SearchName>
Suffix:
<m>
.
*
Query parameters:
<SearchName>
Protocols