Remote control commands
R&S
®
RTP
1730User Manual 1337.9952.02 ─ 12
22.17.10.2 Trigger
The trigger suffix <m> is always 1 and can be omitted. It selects the trigger event: Only
the A-trigger is available for triggering on serial buses.
To trigger on a serial bus, make sure that:
●
TRIGger<m>:SOURce[:SELect] is set to SBUS.
●
The sources of the serial bus are channel signals: use BUS<m>:...:SOURce
commands.
●
Decoding is enabled: BUS<m>[:STATe] is set to ON.
TRIGger<m>:ETHernet:TYPE....................................................................................... 1730
TRIGger<m>:ETHernet:PATTern....................................................................................1731
TRIGger<m>:ETHernet:ERRor:CRC..............................................................................1731
TRIGger<m>:ETHernet:ERRor:LENGth..........................................................................1731
TRIGger<m>:ETHernet:ERRor:PREamble......................................................................1731
TRIGger<m>:ETHernet:FRAMe:CCONdition...................................................................1731
TRIGger<m>:ETHernet:FRAMe:CMAX.......................................................................... 1732
TRIGger<m>:ETHernet:FRAMe:CMIN............................................................................1732
TRIGger<m>:ETHernet:FRAMe:DCONdition...................................................................1732
TRIGger<m>:ETHernet:FRAMe:DMAX.......................................................................... 1733
TRIGger<m>:ETHernet:FRAMe:DMIN............................................................................1733
TRIGger<m>:ETHernet:FRAMe:SCONdition...................................................................1733
TRIGger<m>:ETHernet:FRAMe:SMAX...........................................................................1733
TRIGger<m>:ETHernet:FRAMe:SMIN............................................................................1734
TRIGger<m>:ETHernet:FRAMe:TCONdition...................................................................1734
TRIGger<m>:ETHernet:FRAMe:TMAX...........................................................................1734
TRIGger<m>:ETHernet:FRAMe:TMIN............................................................................1734
TRIGger<m>:ETHernet:TYPE <Type>
Selects the type of frame to be triggered on.
Suffix:
<m>
.
1..3
Parameters:
<Type> STARt | PATTern | ADVFrame | ADVCerror
STARt
Selects to trigger for the start of frame: search for the preamble
and set the trigger instant thereafter.
PATTern
Selects to trigger for a bit pattern (data) to be specified in
TRIGger<m>:ETHernet:PATTern on page 1731.
ADVFrame
Sets the trigger to the advanced frame. You can further define
the values of the frame.
ADVCerror
Sets the trigger to advanced error. You can further enable the
error conditions you want to trigger on.