Remote control commands
R&S
®
RTP
1878User Manual 1337.9952.02 ─ 12
TRIGger<m>:MPHY:PBEGin:CONDition........................................................................ 1889
TRIGger<m>:MPHY:PBEGin:MIN..................................................................................1889
TRIGger<m>:MPHY:PBEGin:MAX.................................................................................1890
TRIGger<m>:MPHY:PFID:CONDition.............................................................................1890
TRIGger<m>:MPHY:PFID:MIN...................................................................................... 1890
TRIGger<m>:MPHY:PFID:MAX..................................................................................... 1891
TRIGger<m>:MPHY:PRPLength....................................................................................1891
TRIGger<m>:MPHY:ERRor:LCMD.................................................................................1891
TRIGger<m>:MPHY:ERRor:LENGth.............................................................................. 1891
TRIGger<m>:MPHY:ERRor:REServed...........................................................................1892
TRIGger<m>:MPHY:ERRor:SYMBol..............................................................................1892
TRIGger<m>:MPHY:ERRor:UNKNown...........................................................................1892
TRIGger<m>:MPHY:TYPE <Type>
Selects the type of frame to be triggered on.
Suffix:
<m>
.
1..3
Parameters:
<Type> START | BURST | ADAPT | LCC | DLPDUSOF | DLPDUCOF |
DLPDUEOF | DLPDUNAC | DLPDUAFC | PACP | TRIGUPR0 |
TRIGUPR1 | TRIGUPR2 | ERRor
START
M-PHY or UniPro start of frame.
BURST
M-PHY burst frame.
ADAPT
M-PHY Adapt frame. This control frame is used for clock/bit syn-
chronization.
LCC
M-PHY LCC frame. This control frame is used for line configura-
tion depending on the LCC Type.
DLPDUSOF | DLPDUCOF | DLPDUEOF | DLPDUNAC |
DLPDUAFC
UniPro DL PDU frame.
PACP
UniPro PACP frame. This control frame is used mainly for power
mode change and L1.5 link management.
TRIGUPR0 | TRIGUPR1 | TRIGUPR2
UniPro Trigger Upper frame. This control frame is used for link
startup sequence.
ERRor
M-PHY or UniPro error frame.
*RST:
START
Protocols

Table of Contents

Other manuals for Rohde & Schwarz RTP Series

Related product manuals