Remote control commands
R&S
®
RTP
1932User Manual 1337.9952.02 ─ 12
BUS<m>:CMSB:NRZ:ENBLe........................................................................................ 1937
BUS<m>:CMSB:NRZ:ENAPolarity.................................................................................1938
BUS<m>:CMSB:NRZ:POLarity......................................................................................1938
BUS<m>:CMSB:NRZ:THReshold:CLCK.........................................................................1938
BUS<m>:CMSB:NRZ:HYSTeresis:CLCK........................................................................1938
BUS<m>:CMSB:NRZ:THReshold:DATA......................................................................... 1939
BUS<m>:CMSB:NRZ:HYSTeresis:DATA........................................................................ 1939
BUS<m>:CMSB:NRZ:THReshold:ENBLe.......................................................................1939
BUS<m>:CMSB:NRZ:HYSTeresis:ENBLe...................................................................... 1939
BUS<m>:CMSB:NRZ:THReshold:PRESet......................................................................1940
BUS<m>:CMSB:NRZ:THReshold:COUPling...................................................................1940
BUS<m>:CMSB:BITRate:ENABle..................................................................................1941
BUS<m>:CMSB:BITRate:VALue....................................................................................1941
BUS<m>:CMSB:GAPTime:ENABle................................................................................1941
BUS<m>:CMSB:GAPTime:VALue..................................................................................1941
BUS<m>:CMSB:ADDFrame..........................................................................................1942
BUS<m>:CMSB:FCOunt?.............................................................................................1942
BUS<m>:CMSB:CLR................................................................................................... 1942
BUS<m>:CMSB:FRAMe<n>:TYPE................................................................................1942
BUS<m>:CMSB:FRAMe<n>:APPend.............................................................................1943
BUS<m>:CMSB:FRAMe<n>:CCOunt?...........................................................................1943
BUS<m>:CMSB:FRAMe<n>:CELL<o>:NAME.................................................................1943
BUS<m>:CMSB:FRAMe<n>:CELL<o>:BITCount............................................................ 1943
BUS<m>:CMSB:FRAMe<n>:CELL<o>:CONDition.......................................................... 1944
BUS<m>:CMSB:FRAMe<n>:CELL<o>:FORMat..............................................................1944
BUS<m>:CMSB:FRAMe<n>:CELL<o>:BITorder..............................................................1945
BUS<m>:CMSB:FRAMe<n>:CELL<o>:CRGB.................................................................1945
BUS<m>:CMSB:EXRBits..............................................................................................1945
BUS<m>:CMSB:FRAMe<n>:CELL<o>:CLMN.................................................................1945
BUS<m>:CMSB:LOAD................................................................................................. 1946
BUS<m>:CMSB:SAVE..................................................................................................1946
BUS<m>:CMSB:CODing <CodingStandard>
Selects the custom serial bus coding standard.
Suffix:
<m>
.
1..4
Parameters:
<CodingStandard> MANC | MANT | NRZ | NRZU
MANC
Manchester (normal polarity)
MANT
Manchester II (inverted polarity).
Note that some additional subtle differences between MANC
and MANT require separate protocols.
NRZ
NRZ (non-return-to-zero), clocked
Protocols