EasyManua.ls Logo

Rohde & Schwarz RTP Series - Page 1940

Rohde & Schwarz RTP Series
2403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTP
1940User Manual 1337.9952.02 ─ 12
Suffix:
<m>
.
1..4
Parameters:
<HystEnable> Range: -25 to 25
Increment: 0.1
*RST: 0.1
Default unit: V
BUS<m>:CMSB:NRZ:THReshold:PRESet <PresetValue>
Sets the NRZ thresholds to predefined or individually definable voltage levels.
Suffix:
<m>
.
1..4
Parameters:
<PresetValue> V05 | V2 | V5 | V7 | MANual
V05
Sets the clock and data threshold to +0.5 V (in case of NRZ
Unclocked: data threshold, only)
V2
Sets the clock and data threshold to +2.0 V (in case of NRZ
Unclocked: data threshold, only)
V5
Sets the clock and data threshold to +5.0 V (in case of NRZ
Unclocked: data threshold, only)
V7
Sets the clock and data threshold to +7.0 V (in case of NRZ
Unclocked: data threshold, only)
MANual
Allows to set individual threshold voltage levels
*RST:
V5
BUS<m>:CMSB:NRZ:THReshold:COUPling <ThresholdCoupling>
Couples the clock and data threshold values for the NRZ Clocked coding standard.
The values are coupled to the same number.
Suffix:
<m>
.
1..4
Parameters:
<ThresholdCoupling> ON | OFF
ON
Activates coupling of the NRZ clock and data threshold values.
OFF
Disables coupling of the NRZ clock and data threshold values.
*RST: ON
Protocols

Table of Contents

Other manuals for Rohde & Schwarz RTP Series