Remote control commands
R&S
®
RTP
1958User Manual 1337.9952.02 ─ 12
:BUS1:CMSB:RESult1:CELL5:STAT? !OK
:BUS1:CMSB:RESult1:CELL5:NAME? !End Delim
:BUS1:CMSB:RESult1:CELL5:VALue? !1HLHL101
To show the results on the screen, use the following commands:
BUS<m>:RESult on page 1549
BUS<m>:CMSB:RCOunt?............................................................................................ 1958
BUS<m>:CMSB:RESult<n>:STATe?.............................................................................. 1958
BUS<m>:CMSB:RESult<n>:STARt?.............................................................................. 1959
BUS<m>:CMSB:RESult<n>:STOP?...............................................................................1959
BUS<m>:CMSB:RESult<n>:TYPE?............................................................................... 1960
BUS<m>:CMSB:RESult<n>:CONE?.............................................................................. 1960
BUS<m>:CMSB:RESult<n>:CTWO?..............................................................................1960
BUS<m>:CMSB:RESult<n>:CTHRee?...........................................................................1960
BUS<m>:CMSB:RESult<n>:CCOunt?............................................................................1961
BUS<m>:CMSB:RESult<n>:CELL<o>:NAME?................................................................1961
BUS<m>:CMSB:RESult<n>:CELL<o>:STARt?................................................................1961
BUS<m>:CMSB:RESult<n>:CELL<o>:STOP?................................................................ 1962
BUS<m>:CMSB:RESult<n>:CELL<o>:STATe?................................................................1962
BUS<m>:CMSB:RESult<n>:CELL<o>:VALue?................................................................1963
BUS<m>:CMSB:RCOunt?
Returns the count number of decoded result frames in a custom serial bus waveform.
Basically, this is the maximum result index <n> when querying results by using
BUS<m>:CMSB:RESult<n>:XXX.
Suffix:
<m>
.
1..4
Return values:
<Count>
Usage: Query only
BUS<m>:CMSB:RESult<n>:STATe?
Returns the overall state of the frame: either OK or the relevant error condition.
R&S RTP-K50 marks each frame with a status that indicates whether the decode suc-
ceeded or not.
Suffix:
<m>
.
1..4
<n> *
Return values:
<State> OK | LENGth | UNKNown | INComplete | CRC | PARity
OK
The frame was decoded normally and conforms to the frame
description.
Protocols