DIGital<m>:DATA:HEADer?
Returns the header of digital channel data
Table 22-16: Header data
Position Meaning Example
1 XStart, acquisition time before trigger, in s -5E-008 = - 50 ns
2 XStop, acquisition time after trigger, in s 5E-008 = 50 ns
3 Record length of the waveform in Samples 1000
4 Number of values per sample interval. For digital
data the result is 1.
1
Suffix:
<m>
.
0..15
Number of the digital channel
Usage: Query only
DIGital<m>:DATA[:VALues]?
Returns the data of the indicated digital channel for transmission from the instrument to
the controlling computer. The data can be used in MATLAB, for example.
Suffix:
<m>
.
0..15
Selects the digital channel.
Return values:
<Data> List of data (0 and 1)
Usage: Query only
BUS<m>:PARallel:DATA:FORMat <DataFormat>
Sets the number format for decoded data values on the display for the indicated paral-
lel bus.
It sets also the number representation for remote data transfer with BUS<m>:
PARallel:DATA[:VALues]?.
Suffix:
<m>
.
1..4
Mixed signal option (MSO, R&S RTP-B1)