Triggers
R&S
®
RTP
266User Manual 1337.9952.02 ─ 12
Alignment / Sync
Sets the alignment pattern.
Remote command:
TRIGger<m>:SERPattern:I32B:APATtern on page 1292
TRIGger<m>:SERPattern:I30B:APATtern on page 1294
Skip start
Sets the skip start value. It is used to compensate for different bit rates between two
communicating ports.
Remote command:
TRIGger<m>:SERPattern:I32B:SSTR on page 1293
TRIGger<m>:SERPattern:I30B:SSTR on page 1294
Skip end
Sets the skip end symbol. It marks the boundary between skip symbols and the rest of
the skip ordered sets.
Remote command:
TRIGger<m>:SERPattern:I32B:SSTP on page 1293
TRIGger<m>:SERPattern:I30B:SSTP on page 1294
Skip bytes
Sets the skip bytes symbols send after a skip end symbol to describe the LSFR state.
Remote command:
TRIGger<m>:SERPattern:I32B:SKAFter on page 1292
TRIGger<m>:SERPattern:I30B:SKAFter on page 1294
Block type
Selects the type of pattern, control block or the data block.
High-speed serial pattern trigger (Option R&S