Protocol analysis
R&S
®
RTP
701User Manual 1337.9952.02 ─ 12
Source Connection
Defines the source and the type of probe used for the respective lane.
Permitted source selections are none, the analog, mathematical, and reference chan-
nels.
CP ← Source Connection
Sets the source of the clock lane.
Remote command:
BUS<m>:DPHY:CP:SOURce on page 1844
DP0/DN0 ← Source Connection
Selects the source of the low-power data lanes.
The "DP0" lane has to be present all the time, hence "Source DP0">"None" is not
allowed.
Remote command:
BUS<m>:DPHY:DPZero:SOURce on page 1846
BUS<m>:DPHY:DNZero:SOURce on page 1846
DP1/DP2/DP3 ← Source Connection
Selects the source of the high-speed data lanes.
Remote command:
BUS<m>:DPHY:DPONe:SOURce on page 1846
BUS<m>:DPHY:DPTWo:SOURce on page 1846
BUS<m>:DPHY:DPTHree:SOURce on page 1846
Probe ← Source Connection
Selects the type of probe used for the respective lane. The D-PHY low-power mode
uses a single-ended signal, while the high-speed mode signaling is differential.
Remote command:
BUS<m>:DPHY:CP:PROBe on page 1843
BUS<m>:DPHY:DNZero:PROBe on page 1847
BUS<m>:DPHY:DPZero:PROBe on page 1847
BUS<m>:DPHY:DPONe:PROBe on page 1847
BUS<m>:DPHY:DPTWo:PROBe on page 1847
BUS<m>:DPHY:DPTHree:PROBe on page 1847
Data Rate
Sets a data rate.
Remote command:
BUS<m>:DPHY:DRATe on page 1844
BUS<m>:DPHY:DSPData on page 1844
HS Threshold
Sets the threshold value for the digitization of high-speed data line.