Protocol analysis
R&S
®
RTP
732User Manual 1337.9952.02 ─ 12
Field name / Condition Summary / Enable
This table lists the field numbers and names in the selected frame together with a sum-
mary of the user settings of checking conditions for each field and a checkbox to
enable the checking.
Select a field in the table to specify the checking conditions for this field in the "Set
details" dialog.
The SSIC trigger frames and fields are the same as for USB3.1, see "Frame types"
on page 830.
Remote command:
TRIGger<m>:MPHY:SSIC:FRENable on page 1921
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:ENABle on page 1922
Data
Defines for the selected field, how a data check is executed.
"Condition"
Defining specific data or a data range requires to set the operator to
one of the following conditions: equal, not equal, less than, less than
or equal, greater than, greater than or equal, in range, out of range.
"Min"
Specifies data or sets the start value of a data range.
"Max"
Sets the end value of a data range, if "Condition" is set to "In range"
or "Out of range".
Remote command:
TRIGger<m>:MPHY:SSIC:DOPerator on page 1923
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:DOPerator on page 1923
TRIGger<m>:MPHY:SSIC:DMIN on page 1923
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:DMIN on page 1923
TRIGger<m>:MPHY:SSIC:DMAX on page 1923
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:DMAX on page 1923
BitState
Defines the bit state to be checked for the selected field. Permitted bit states are "1",
"0" or "X" (do not care).
Remote command:
TRIGger<m>:MPHY:SSIC:BIT on page 1922
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:BIT on page 1922
Index
Defines for the selected field, how an index check is executed.
"Condition"
Defining a specific index or an index range requires to set the opera-
tor to one of the following conditions: equal, in range.
"Min"
Specifies the index or sets the start value of an index range.
"Max"
Sets the end value of an index range, if "Condition" is set to "In
range".
Remote command:
TRIGger<m>:MPHY:SSIC:IOPerator on page 1925
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:IOPerator on page 1925
M-PHY and USB SSIC (option R&S