Protocol analysis
R&S
®
RTP
799User Manual 1337.9952.02 ─ 12
ST
Selects the start of frame code of the frame pattern; available only in search criteria
type "Data". Permissible frame patterns are: Clause 22, Clause 45, or Any
Remote command:
SEARch:TRIGger:MDIO:ST on page 2000
OP
Selects the Type of Frame code (or OP code, OpCode, operation code); available only
in search criteria type "Data". Available frame types are: Address, Write, Read, Post
Read, or Any
Remote command:
SEARch:TRIGger:MDIO:FRAMetype on page 1999
PHYAD/PRTAD
Sets the physical address or port address (5 bits) of the frame pattern; available only in
search criteria type "Data".
Remote command:
SEARch:TRIGger:MDIO:PHYS on page 1999
REGAD/DEVAD
Sets the register address or device address (5 bits) of the frame pattern; available only
in search criteria type "Data".
Remote command:
SEARch:TRIGger:MDIO:REGI on page 1999
DATA/ADDRESS
Defines the payload data pattern or address pattern (16 bits); available only in search
criteria type "Data".
Remote command:
SEARch:TRIGger:MDIO:DATA on page 1998
13.17.5.2 MDIO search results
To get search results, "Enable" the search. You can minimize, shift or close the search
dialog.
The search results are listed in the search result table and marked in the waveform by
blue lines.
For an introduction to search results, see:
Chapter 11.1.2, "Search results", on page 449
Chapter 11.4.2, "Display zoom settings", on page 468
Remote commands:
SEARch:RESult:MDIO:WCOunt? on page 2004
SEARch:RESult:MDIO:WORD<m>:STATe? on page 2003
SEARch:RESult:MDIO:WORD<m>:STARt? on page 2002
MDIO (option R&S
RTP-K55)