Remote control commands
R&S
®
RTP
1170User Manual 1337.9952.02 ─ 12
<Source> C1W1 | C1W2 | C1W3 | C2W1 | C2W2 | C2W3 | C3W1 | C3W2 |
C3W3 | C4W1 | C4W2 | C4W3 | M1 | M2 | M3 | M4 | M5 | M6 |
M7 | M8 | R1 | R2 | R3 | R4 | XY1 | XY2 | XY3 | XY4 |
MRESult1 | MRESult2 | MRESult3 | MRESult4 | MRESult5 |
MRESult6 | MRESult7 | MRESult8 | QUICk | QUICK | SBUS1 |
SBUS2 | SBUS3 | SBUS4 | D0 | D1 | D2 | D3 | D4 | D5 | D6 |
D7 | D8 | D9 | D10 | D11 | D12 | D13 | D14 | D15 | MSOB1 |
MSOB2 | MSOB3 | MSOB4 | TRK1 | TRK2 | TRK3 | TRK4 |
TRK5 | TRK6 | TRK7 | TRK8 | SG1 | SG2 | SG3 | SG4 | SG5 |
SG6 | SG7 | SG8 | SG1TL1 | SG1TL2 | SG2TL1 | SG2TL2 |
SG3TL1 | SG3TL2 | SG4TL1 | SG4TL2 | SG5TL1 | SG5TL2 |
SG6TL1 | SG6TL2 | SG7TL1 | SG7TL2 | SG8TL1 | SG8TL2 |
Z1V1 | Z1V2 | Z1V3 | Z1V4 | Z1I1 | Z1I2 | Z1I3 | Z1I4 | Z2V1 |
Z2V2 | Z2V3 | Z2V4 | Z2I1 | Z2I2 | Z2I3 | Z2I4 | DIFF1 | DIFF2 |
COMMON1 | COMMON2 | EYE1 | EYE2 | EYE3 | EYE4 |
TDRZ | TDRH | TDRR | SEYE1 | SEYE2
Waveform to that the label belongs, see Chapter 22.4.1, "Wave-
form suffix", on page 1141.
<LabelText>
String with the label text that is shown on the display
<PositionMode> ABS | REL
ABS
Position in time and voltage values, or in other units depending
on the waveform character. Absolute positions move with the
waveform display when the scales, the vertical position or offset,
or the reference point are changed.
REL
Fixed label position in percent of the screen counting from the
upper left corner.
<XPositon> Horizontal position of the label text. Values, range and unit
depend on the position mode, the waveform position and scal-
ing. For relative position mode, the range is 0 to 100 %.
<YPositon> Vertical position of the label text. Values, range and unit depend
on the position mode, the waveform position and scaling. For
relative position mode, the range is 0 to 100 %.
Example:
DISPlay:SIGNal:LABel:ADD 'Label1', C1W1, 'Label
on C1W1', REL, 20, 20
Adds the label text 'Label on C1W1' to waveform1 of channel1 at
relative position 20% from the upper left corner of the screen.
The label ID is 'Label1'.
Example:
DISPlay:SIGNal:LABel:ADD 'Label1', C2W1, 'Label
on C2W1', ABS, 10e-09, 0.1
Adds the label text 'Label on C2W1' to waveform1 of channel2 at
absolute position 10 ns and 0.1 V. The label ID is 'Label1'.