Remote control commands
R&S
®
RTP
1498User Manual 1337.9952.02 ─ 12
SEARch:TRIGger:LEVel:WINDow:LOWer <SearchName>, <SignalSource>, <Value>
SEARch:TRIGger:LEVel:WINDow:LOWer? <Key>, <SignalSource>
SEARch:TRIGger:LEVel:WINDow:UPPer <SearchName>, <SignalSource>, <Value>
SEARch:TRIGger:LEVel:WINDow:UPPer? <Key>, <SignalSource>
Set the lower and upper voltage limits for the window.
Parameters:
<Value> Voltage value
Parameters for setting and query:
<SearchName> String with the name of the search
<SignalSource> C1W1 | C1W2 | C1W3 | C2W1 | C2W2 | C2W3 | C3W1 | C3W2 |
C3W3 | C4W1 | C4W2 | C4W3 | M1 | M2 | M3 | M4 | M5 | M6 |
M7 | M8 | R1 | R2 | R3 | R4 | D0 | D1 | D2 | D3 | D4 | D5 | D6 |
D7 | D8 | D9 | D10 | D11 | D12 | D13 | D14 | D15 | TRK1 | TRK2 |
TRK3 | TRK4 | TRK5 | TRK6 | TRK7 | TRK8 | Z1V1 | Z1V2 |
Z1V3 | Z1V4 | Z1I1 | Z1I2 | Z1I3 | Z1I4 | Z2V1 | Z2V2 | Z2V3 |
Z2V4 | Z2I1 | Z2I2 | Z2I3 | Z2I4
Source of the search, see Chapter 22.4.2, "Waveform parame-
ter", on page 1145
Usage: Asynchronous command
22.15.11 Data2clock search conditions
Data level setting: SEARch:TRIGger:LEVel[:VALue] on page 1484
SEARch:TRIGger:SETHold:CEDGe...............................................................................1498
SEARch:TRIGger:SETHold:CLEVel............................................................................... 1499
SEARch:TRIGger:SETHold:CSOurce.............................................................................1499
SEARch:TRIGger:SETHold:HTIMe................................................................................ 1499
SEARch:TRIGger:SETHold:STIMe................................................................................ 1500
SEARch:TRIGger:SETHold:CEDGe <SearchName>,<ClockEdge>
SEARch:TRIGger:SETHold:CEDGe? <SearchName>
Sets the edge of the clock signal to define the time reference point for the setup and
hold time.
Parameters:
<ClockEdge> POSitive | NEGative | EITHer
See Chapter 22.4.3, "Slope parameter", on page 1147.
*RST: POSitive
Parameters for setting and query:
<SearchName>