EasyManua.ls Logo

Rohde & Schwarz RTP044 - Page 1633

Rohde & Schwarz RTP044
2403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTP
1633User Manual 1337.9952.02 ─ 12
Return values:
<AckValue> To set the value format, use FORMat:BPATtern.
The values below range, increment and reset are decimal
values.
Range: 0 to 1
*RST: 0
Usage: Query only
BUS<m>:CAN:FRAMe<n>:BITRate?
Returns the primary bit rate.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
Selects the frame.
Return values:
<PrimaryBitRate> Range: 0 to 100000000000
Increment: 1
*RST: 0
Default unit: bps
Usage: Query only
BUS<m>:CAN:FRAMe<n>:CSValue?
Returns the CRC sequence value of the selected frame.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
Selects the frame.
Return values:
<ChecksumValue> To set the value format, use FORMat:BPATtern.
The values below range, increment and reset are decimal
values.
Range: 0 to 2097151
*RST: 0
Usage: Query only
BUS<m>:CAN:FRAMe<n>:DLCValue?
Returns the data length code of the selected frame - the number of data bytes in the
frame.