Remote control commands
R&S
®
RTP
1699User Manual 1337.9952.02 ─ 12
Usage: Query only
BUS<m>:MILStd:WORD<n>:INFO?
Returns the info value for the specified word.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
Selects the word.
Return values:
<FrameInfo> Range: 0 to 2047
Increment: 1
*RST: 0
Usage: Query only
BUS<m>:MILStd:WORD<n>:RTADdress?
Returns the RT address for the selected word.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
Selects the word.
Return values:
<FrameRta> Range: 0 to 31
Increment: 1
*RST: 0
Usage: Query only
BUS<m>:MILStd:WORD<n>:STARt?
Return the start time of the selected word.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
Selects the word.
Return values:
<FrameStart> Range: -100E+24 to 100E+24
Increment: 100E-12
*RST: 0
Default unit: s