Remote control commands
R&S
®
RTP
1998User Manual 1337.9952.02 ─ 12
Return values:
<Translation>
Usage: Query only
BUS<m>:MDIO:WORD<n>:TYPE?
Returns the OpCode (= operation code or frame type) in the present acquisition of the
selected word and the selected serial bus.
Suffix:
<m>
.
1..4
<n> *
Return values:
<FrameType> Range: 0 to 3
Increment: 1
*RST: 0
The parameter value "0" represents Clause 45, and "1" stands
for Clause 22.
The values "2" and "3" do not correspond with any legal parame-
ters according to the standard, but they can be searched for.
Usage: Query only
22.17.18.4 Search settings
SEARch:TRIGger:MDIO:DATA...................................................................................... 1998
SEARch:TRIGger:MDIO:FRAMetype............................................................................. 1999
SEARch:TRIGger:MDIO:PHYS......................................................................................1999
SEARch:TRIGger:MDIO:REGI.......................................................................................1999
SEARch:TRIGger:MDIO:ST.......................................................................................... 2000
SEARch:TRIGger:MDIO:TYPE......................................................................................2000
SEARch:TRIGger:MDIO:DATA <SearchName>,<Data>
SEARch:TRIGger:MDIO:DATA? <SearchName>
Allows to define the 16-bit payload data pattern (both in Clause 22 or Clause 45) or the
address pattern (in Clause 45, only) to search for; available only in search criteria type
"Data".
Parameters:
<Data>
Parameters for setting and query:
<SearchName>