Remote control commands
R&S
®
RTP
2073User Manual 1337.9952.02 ─ 12
Example:
SEARch:TRIGger:USBThree:FRAMe1:ENABle ON
Enables searching for the TSEQ frame.
SEARch:TRIGger:USBThree:FRENable "TS1" ON
Enables searching for the TS1 frame.
SEARch:TRIGger:USBThree:FIENable <SearchName>,<Frame>, <Field>,
<Enabler>
SEARch:TRIGger:USBThree:FRAMe<m>:FLD<n>:ENABle
<SearchName>,<CondEnabler>
SEARch:TRIGger:USBThree:FRAMe<m>:FLD<n>:ENABle? <SearchName>
Enables or disables the checking condition for searching a specific field of the selected
frame.
Suffix:
<m>
.
*
Specifies the frame.
<n> *
Specifies the field number within the frame.
Parameters:
<CondEnabler> ON | OFF
ON
Checking condition enabled
OFF
Checking condition disabled
*RST: OFF
Parameters for setting and query:
<SearchName> String with the name of the search.
Example:
SEARch:TRIGger:USBThree:FRAMe1:FLD1:ENABle ON
Enables searching for the Symbol field of the TSEQ frame.
SEARch:TRIGger:USBThree:FRENable "TS1", "Loop"
ON
Enables searching for the Loop field of the TS1 frame.
SEARch:TRIGger:USBThree:DOPerator <SearchName>,<Frame>, <Field>,
<Operator>
SEARch:TRIGger:USBThree:FRAMe<m>:FLD<n>:DOPerator
<SearchName>,<DataOperator>
SEARch:TRIGger:USBThree:FRAMe<m>:FLD<n>:DOPerator? <SearchName>
Sets the operator to set a specific data pattern to be searched in the selected field of
the selected frame.
Suffix:
<m>
.
*
Specifies the field number within the frame.
Protocols