Remote control commands
R&S
®
RTP
2116User Manual 1337.9952.02 ─ 12
Return values:
<State> OK | PAR | ESC | AMB | INComplete
PAR: parity error
ESC: escape
AMB: ambiguous
*RST: OK
Usage: Query only
BUS<m>:SWIRe:RESults:FRAMe<n>:FLD<o>:STOP?
Returns the stop time of the field with the selected field number within the frame with
the selected frame number.
Suffix:
<m>
.
1..4
<n> *
Selects the frame number.
<o> *
Selects the field number.
Return values:
<Stop> Range: -100E+24 to 100E+24
Increment: 100E-12
*RST: 0
Default unit: s
Usage: Query only
BUS<m>:SWIRe:RESults:FRAMe<n>:FLD<o>:TYPE?
Returns the type of the field with the selected field number within the frame with the
selected frame number.
Suffix:
<m>
.
1..4
<n> *
Selects the frame number.
<o> *
Selects the field number.
Return values:
<FrameByteValue>
Usage: Query only