Protocol analysis
R&S
®
RTP
575User Manual 1337.9952.02 ─ 12
FD bits
For standard settings " CAN FD" and "Any", you can search for CAN FD-specific bits.
For details, see "FD bits" on page 567.
The setting is available in CAN FD option R&S RTP-K9.
Remote command:
SEARch:TRIGger:CAN:FDATa[:FDF] on page 1645
SEARch:TRIGger:CAN:FDATa:BRS on page 1645
SEARch:TRIGger:CAN:FDATa:ESI on page 1645
Data setup: DLC, NDB, Condition, Data min, Data max
The data setup consists of the number of bytes, the condition, and one or two data pat-
terns.
The data setup settings are the same as in the CAN trigger setup, see "Data setup:
DLC, NDB, Transfer, Condition, Data min, Data max" on page 568.
The data condition setting is also used for symbolic signal search, see Chap-
ter 13.5.6.3, "Symbolic search", on page 579.
Remote command:
SEARch:TRIGger:CAN:DCONdition on page 1640
SEARch:TRIGger:CAN:DMIN on page 1641
SEARch:TRIGger:CAN:DMAX on page 1641
SEARch:TRIGger:CAN:DLCCondition on page 1641
SEARch:TRIGger:CAN:DLC on page 1642
SEARch:RESult:CAN:FRAMe<m>:NDBYtes? on page 1642
Data position
The data position sets the location in the data field where the instrument looks for the
specified data pattern.
The setting is available in CAN FD option R&S RTP-K9.
The position can be defined if the data field of the frame is longer than 8 bytes - if DLC
9.
For details, see "Data position" on page 569.
Remote command:
SEARch:TRIGger:CAN:FDATa:DPOPerator on page 1642
SEARch:TRIGger:CAN:FDATa:DPOSition on page 1643
SEARch:TRIGger:CAN:FDATa:DPTO on page 1643
Error Condition
Selects the error type to be searched for. You can select one or more error types as
search condition.
The error types are the same as in the CAN trigger setup, see "Error conditions"
on page 569.
Remote command:
SEARch:TRIGger:CAN:CRCerror on page 1644
SEARch:TRIGger:CAN:BITSterror on page 1644
SEARch:TRIGger:CAN:FORMerror on page 1644
CAN and CAN FD (option R&S
RTP-K3/K9)