Protocol analysis
R&S
®
RTP
630User Manual 1337.9952.02 ─ 12
Show thresholds
If enabled, the threshold levels are displayed in the diagram.
Remote command:
BUS<m>:THReshold on page 1549
13.9.2.2 Ethernet display settings
Access: [Protocol] > "Display" tab.
For common display settings, see Chapter 13.1.3, "Display", on page 514.
To enhance the decode possibilities of the Ethernet protocol, you can use an additional
setting in the "Display" tab: "Decode layer".
Ethernet Specific Label Settings
Label lists are protocol-specific. An Ethernet label file contains two values for each
identifier:
"Ethernet Header Display": the Ethernet header display value
"Symbolic label": symbolic name of the header, specifying its function
# ----------------------------------------------------------------------------
@FILE_VERSION = 1.00
@PROTOCOL_NAME = ethernet
# ---------------------------------------------------------------------------
# Labels for Ethernet protocol
# Column order: Ethernet Header Display, Label
#-----------------------------------------------------------------------------
# Supported MAC Address Format
# xx:xx:xx standard 24 bit manufactory header
Ethernet 10BASE-T and 100BASE-TX (option R&S
RTP-K8)